Case
Home > Case

Explore the use of liquid nitrogen storage tanks

By Manager
Date: Feb 28, 2020
In recent years, with its many advantages, liquid nitrogen storage tanks have been highly sought after in the industry, and once became the main storage device for liquid nitrogen. However, for most staff, liquid nitrogen storage tanks are still relatively unfamiliar. In order to ensure the application of liquid nitrogen storage tanks, the cryogenic storage tank manufacturers have specially compiled some knowledge about the use of liquid nitrogen storage tanks. If you are interested, then you may wish to continue reading the following articles.

1.The meaning of liquid nitrogen storage tank:
It refers to storage tanks that contain liquid nitrogen. Liquid nitrogen is a low-temperature liquid of -182 degrees. Therefore, this storage tank is also referred to as a low-temperature storage tank.

2.Purpose of liquid nitrogen storage tank:
The more common use of storage tanks is to supply nitrogen, according to the nitrogen used for deep breathing in hospital wards, nitrogen blowing in steel furnaces of steel plants, nitrogen for metal cutting, nitrogen-rich combustion in boilers, and liquid nitrogen to gaseous nitrogen ionization to make odorous nitrogen. Very extensive.
3.Size of liquid nitrogen storage tank:
Liquid nitrogen storage tanks usually have two types: vertical and horizontal. The storage tank has an inner container and an outer container. The inner container is made of 304 stainless steel. The outer container is made of ordinary carbon steel. . Divided by filling volume: 5 cubic, 10 cubic, 15 cubic, 20 cubic, 30 cubic, 50 cubic, 100 cubic, 150 cubic, can also be customized according to the needs of the field use.

4.Installation of liquid nitrogen storage tank:
The storage tank is developed and constructed in accordance with the GB150 steel pressure vessel and GB18442 cryogenic adiabatic pressure vessel. The liquid nitrogen station macro plan shall be in accordance with the GB50030 nitrogen station design specification. The distance between the liquid nitrogen tanks should be compared with the design requirements of the nitrogen station. The installation unit needs to have the pressure vessel installation qualification before it can be constructed and installed.
Last article:
Next article:
Send Your Inquiry
We not only provide a good product, but also provide high quality service. If you are interested in our products,
you can contact us in the following ways.
Your name:
*Your email:
Your phone:
*Your inquiry:
Home
Products
Tel
E-mail
Inquiry