Product Category
Safe use of Dewar tank
Date: May 27, 2020
Cryogenic Dewars generally have 4 valves, namely liquid use valve, gas use valve, vent valve, and boost valve. There are also gas-phase pressure gauges and level gauges. Dewars are not only equipped with safety valves, but also bursting discs. Once the pressure of the gas in the bottle exceeds the take-off pressure of the safety valve, the safety valve will immediately take off and automatically exhaust the pressure. If the safety valve fails or the gas cylinder accidentally causes the vacuum layer to be damaged, the pressure in the bottle rises sharply to a certain degree, and the rupture disks it sets will automatically rupture, thereby promptly reducing the pressure in the bottle to atmospheric pressure .
The cryogenic Dewar tank stores medical liquid oxygen, which greatly increases the oxygen storage capacity. The oxygen storage capacity of a Dewar cylinder with a capacity of 175 L is equivalent to the oxygen storage capacity of 28 high-pressure gas
cylinders with a capacity of 40 L, which greatly reduces the transportation pressure and reduces the capital investment. There are 2 ways to use Dewar tank:
The cryogenic Dewar tank stores medical liquid oxygen, which greatly increases the oxygen storage capacity. The oxygen storage capacity of a Dewar cylinder with a capacity of 175 L is equivalent to the oxygen storage capacity of 28 high-pressure gas
cylinders with a capacity of 40 L, which greatly reduces the transportation pressure and reduces the capital investment. There are 2 ways to use Dewar tank:
(1) Dewar gas usage valve, connect one end of the high-pressure metal hose to the Dewar gas usage valve and the other end to the busbar, first open the valve, then slowly open the gas usage valve, you can use, large Most hospitals can meet gas requirements using only gas-phase valves.
(2) Dewar tank liquid use valve, connect the pipe where the Dewar liquid valve is located to the carburetor with a high-pressure metal hose, the size of the gasifier is configured according to the amount of gas used, and the seamless steel pipe is used to transport the gas. Pressure valve, safety valve, pressure gauge to control the safety of the gas supply system, so that not only can use gas conveniently and stably, but also ensure safe use. When using the Dewar, please confirm the connection before opening the liquid use valve. If the gas pressure does not meet the requirements for use, you can open the booster valve. The pressure will rise and meet the requirements for use in a few minutes.
(2) Dewar tank liquid use valve, connect the pipe where the Dewar liquid valve is located to the carburetor with a high-pressure metal hose, the size of the gasifier is configured according to the amount of gas used, and the seamless steel pipe is used to transport the gas. Pressure valve, safety valve, pressure gauge to control the safety of the gas supply system, so that not only can use gas conveniently and stably, but also ensure safe use. When using the Dewar, please confirm the connection before opening the liquid use valve. If the gas pressure does not meet the requirements for use, you can open the booster valve. The pressure will rise and meet the requirements for use in a few minutes.
Last article:
Next article:
Send Your Inquiry
We not only provide a good product, but also provide high quality service. If you are interested in our products,
you can contact us in the following ways.
you can contact us in the following ways.