Content

According to the “Pressure Vessel Safety Skills Supervision Regulations”, inspection holes should be opened for containers larger than ?300. The inspection holes are manholes, hand holes and cocks. check. ③The pressure of the hydraulic test is lower than the specified value: the planned pressure of a liquefied gas storage tank is 1.1MPa, the planned temperature is 200°C, the raw material is Q235B, and the test pressure is 1.37MPa. According to the GB150 rules: hydraulic pressure test pressure Pt=1.25[a]/[a]t P, the calculated test pressure should be 1.4MPa, and the correction coefficient was not considered in the planning.

 