Home » liquid oxygen tank » Preparation work before using the cryogenic liquid oxygen storage tank

Preparation work before using the cryogenic liquid oxygen storage tank

Before using the cryogenic tank, it should be purged with liquid oxygen from a tanker truck to ensure that the dew point of the gas in the tank is no higher than -45°C before it can be used.

Rated 4.5/5 based on 570 customer reviews
Share:
Content

Preparation work before using the cryogenic liquid oxygen storage tank

① Before using the cryogenic tank, it should be purged with liquid oxygen from a tanker truck to ensure that the dew point of the gas in the tank is no higher than -45°C before it can be used.

② Check whether the pressure gauge, liquid level gauge, valves, etc. are complete and intact, and whether the operation instructions are normal.

③ Before filling the equipment with liquid, close all outlet valves and vent valves, and introduce oxygen to the working pressure. Check the air tightness of the inner barrel and piping system of the storage tank, and the inspection is qualified.

Inquiry


    More liquid oxygen tank