Treatment method for deformation of liquid oxygen storage tank.

Rated 4.7/5 based on 396 customer reviews
Share:
Content

For slight bulging deformation, if the deformation area is not too large and does not affect other parts of the liquid oxygen storage tank, then if the liquid oxygen storage tank material has good weldability, you can consider using digging and patching. That is, dig out the local bulging part, and then use the same shape and material plate for repair welding. After welding, the weld is technically inspected according to the original technical requirements of the liquid oxygen storage tank.